Abstract
Monitoring of biogenic sulfide is important because acid volatile sulfides (AVS) represent a reactive pool responsible for immobilization of toxic metals. We propose a new sulfide paper sensor method for semiquantitative determination of AVS in which developed color is compared to a reference chart. The method was validated against the ion-selective microelectrode and the purge-and-trap methods. For fieldwork, readings should fall within 1 to 10 μmoles S 2– . Considering that the volume of soil used ranged between 1 and 16 cm 3 , the corresponding soil sulfides concentration range spans from 0.06 to 10 mmoles S 2– cm −3 . The sulfide paper sensor method is highly suitable for field screening and has sensitivity levels comparable to laboratory methods. Environ Toxicol Chem 2018;37:3025–3031.
| Originalsprog | Engelsk |
|---|---|
| Tidsskrift | Environmental Toxicology and Chemistry |
| Vol/bind | 37 |
| Udgave nummer | 12 |
| Sider (fra-til) | 3025-3031 |
| Antal sider | 7 |
| ISSN | 0730-7268 |
| DOI | |
| Status | Udgivet - 2018 |
| Udgivet eksternt | Ja |
Citationsformater
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS