T1 - Adaptation of a Commercially Available Enzyme Linked Immunosorbent Assay (ELISA) for the Determination of Thyroxine in Canine Plasma Samples
AU - Jensen, A. L.
AU - Høier, R.
AU - Poulsen, J. S.D.
PY - 1992
Y1 - 1992
N2 - The purpose of the present study was to modify a previously evaluated enzyme linked immunosorbent assay (Larsson and Lumsden, 1980) for the determination of the thyroxine (T4) concentration in canine plasma samples. The test kit Enzymun‐Test®Boehringer Mannheim for determination of T4 concentrations in human plasma was used in connection with the analyzer system Enzymun‐Test®Boehringer Mannheim System ES‐33. The assay protocol originally used by Larsson and Lumsden (1980) was modified by including an additional standard, prolongation of the incubation period for the immunoreaction and the enzymeassay, and reduction of the amount of T4 conjugate. The intra‐ and interassay coefficient of variations ranged from 3.8% to 12.5%. The detection limit of the assay was 3.9nmol/l which is well below the T4 concentration observed in plasma from healthy dogs, and the T4 concentrations determined in plasma from healthy dogs before and 3 hours after administration of TRH (38.0 ± 7.4 nmol/l and 51.8 ± 8.5 nmol/l, respectively) were comparable to those reported in the literature.
AB - The purpose of the present study was to modify a previously evaluated enzyme linked immunosorbent assay (Larsson and Lumsden, 1980) for the determination of the thyroxine (T4) concentration in canine plasma samples. The test kit Enzymun‐Test®Boehringer Mannheim for determination of T4 concentrations in human plasma was used in connection with the analyzer system Enzymun‐Test®Boehringer Mannheim System ES‐33. The assay protocol originally used by Larsson and Lumsden (1980) was modified by including an additional standard, prolongation of the incubation period for the immunoreaction and the enzymeassay, and reduction of the amount of T4 conjugate. The intra‐ and interassay coefficient of variations ranged from 3.8% to 12.5%. The detection limit of the assay was 3.9nmol/l which is well below the T4 concentration observed in plasma from healthy dogs, and the T4 concentrations determined in plasma from healthy dogs before and 3 hours after administration of TRH (38.0 ± 7.4 nmol/l and 51.8 ± 8.5 nmol/l, respectively) were comparable to those reported in the literature.
UR - http://www.scopus.com/inward/record.url?scp=84995046162&partnerID=8YFLogxK
U2 - 10.1111/j.1439-0442.1992.tb00238.x
DO - 10.1111/j.1439-0442.1992.tb00238.x
M3 - Journal article
C2 - 1492506
AN - SCOPUS:84995046162
SN - 0931-184X
VL - 39
SP - 741
EP - 746
JO - Journal of Veterinary Medicine Series A
JF - Journal of Veterinary Medicine Series A
IS - 1-10
ER -