TY - JOUR
T1 - Determination of nutritional parameters of yoghurts by FT Raman spectroscopy
AU - Czaja, Tomasz
AU - Baranowska, Maria
AU - Mazurek, Sylwester
AU - Szostak, Roman
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/5/5
Y1 - 2018/5/5
N2 - FT-Raman quantitative analysis of nutritional parameters of yoghurts was performed with the help of partial least squares models. The relative standard errors of prediction for fat, lactose and protein determination in the quantified commercial samples equalled to 3.9, 3.2 and 3.6%, respectively. Models based on attenuated total reflectance spectra of the liquid yoghurt samples and of dried yoghurt films collected with the single reflection diamond accessory showed relative standard errors of prediction values of 1.6−5.0% and 2.7−5.2%, respectively, for the analysed components. Despite a relatively low signal-to-noise ratio in the obtained spectra, Raman spectroscopy, combined with chemometrics, constitutes a fast and powerful tool for macronutrients quantification in yoghurts. Errors received for attenuated total reflectance method were found to be relatively higher than those for Raman spectroscopy due to inhomogeneity of the analysed samples.
AB - FT-Raman quantitative analysis of nutritional parameters of yoghurts was performed with the help of partial least squares models. The relative standard errors of prediction for fat, lactose and protein determination in the quantified commercial samples equalled to 3.9, 3.2 and 3.6%, respectively. Models based on attenuated total reflectance spectra of the liquid yoghurt samples and of dried yoghurt films collected with the single reflection diamond accessory showed relative standard errors of prediction values of 1.6−5.0% and 2.7−5.2%, respectively, for the analysed components. Despite a relatively low signal-to-noise ratio in the obtained spectra, Raman spectroscopy, combined with chemometrics, constitutes a fast and powerful tool for macronutrients quantification in yoghurts. Errors received for attenuated total reflectance method were found to be relatively higher than those for Raman spectroscopy due to inhomogeneity of the analysed samples.
KW - Attenuated total reflectance
KW - Multivariate calibration
KW - Quantitative analysis
KW - Raman
KW - Yoghurt
UR - http://www.scopus.com/inward/record.url?scp=85042643962&partnerID=8YFLogxK
U2 - 10.1016/j.saa.2018.02.054
DO - 10.1016/j.saa.2018.02.054
M3 - Journal article
C2 - 29499570
AN - SCOPUS:85042643962
VL - 196
SP - 413
EP - 417
JO - Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
JF - Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
SN - 1386-1425
ER -