Does cup position differ between trabecular metal and titanium cups? A radiographic propensity score matched study of 300 hips

Inari Laaksonen*, Natalie Hjelmberg, Kirill Gromov, Antti E. Eskelinen, Ola Rolfson, Henrik Malchau, Anders Troelsen, Keijo T. Mäkelä, Maziar Mohaddes

*Corresponding author af dette arbejde

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

14 Downloads (Pure)

Abstract

Background and purpose — The use of trabecular metal cups in primary total hip arthroplasty (THA) is increasing, despite the survival of Continuum cups being slightly inferior compared with other uncemented cups in registries. This difference is mainly explained by a higher rate of dislocation revisions. Cup malpositioning is a risk factor for dislocation and, being made of a highly porous material, Continuum cups might be more difficult to position. We evaluated whether Continuum cups had worse cup positioning compared with other uncemented cups. Patients and methods — Based on power calculation, 150 Continuum cups from 1 center were propensity score matched with 150 other uncemented cups from 4 centers. All patients had an uncemented stem, femoral head size of 32 mm or 36 mm, and BMI between 19 and 35. All operations were done for primary osteoarthrosis through a posterior approach. Patients were matched using age, sex, and BMI. Cup positioning was measured from anteroposterior pelvic radiograph using the Martell Hip Analysis Suite software. Results — There was no clinically relevant difference in mean inclination angle between the study group and the control group (43° [95% CI 41–44] and 43° [CI 42–45], respectively). The study group had a larger mean anteversion angle compared with the control group, 19° (CI 18–20) and 17° (CI 15–18) respectively. Interpretation — Continuum cups had a greater anteversion compared with the other uncemented cups. However, the median anteversion was acceptable in both groups and this difference does not explain the larger dislocation rate in the Continuum cups observed in earlier studies.

OriginalsprogEngelsk
TidsskriftActa Orthopaedica
Vol/bind91
Udgave nummer6
Sider (fra-til)682-686
Antal sider5
ISSN1745-3674
DOI
StatusUdgivet - 2020

Citationsformater