TY - JOUR
T1 - ESUR/ESUI consensus statements on multi-parametric MRI for the detection of clinically significant prostate cancer
T2 - quality requirements for image acquisition, interpretation and radiologists’ training
AU - de Rooij, Maarten
AU - Israël, Bas
AU - Tummers, Marcia
AU - Ahmed, Hashim U.
AU - Barrett, Tristan
AU - Giganti, Francesco
AU - Hamm, Bernd
AU - Løgager, Vibeke
AU - Padhani, Anwar
AU - Panebianco, Valeria
AU - Puech, Philippe
AU - Richenberg, Jonathan
AU - Rouvière, Olivier
AU - Salomon, Georg
AU - Schoots, Ivo
AU - Veltman, Jeroen
AU - Villeirs, Geert
AU - Walz, Jochen
AU - Barentsz, Jelle O.
PY - 2020
Y1 - 2020
N2 - Objectives: This study aims to define consensus-based criteria for acquiring and reporting prostate MRI and establishing prerequisites for image quality. Methods: A total of 44 leading urologists and urogenital radiologists who are experts in prostate cancer imaging from the European Society of Urogenital Radiology (ESUR) and EAU Section of Urologic Imaging (ESUI) participated in a Delphi consensus process. Panellists completed two rounds of questionnaires with 55 items under three headings: image quality assessment, interpretation and reporting, and radiologists’ experience plus training centres. Of 55 questions, 31 were rated for agreement on a 9-point scale, and 24 were multiple-choice or open. For agreement items, there was consensus agreement with an agreement ≥ 70% (score 7–9) and disagreement of ≤ 15% of the panellists. For the other questions, a consensus was considered with ≥ 50% of votes. Results: Twenty-four out of 31 of agreement items and 11/16 of other questions reached consensus. Agreement statements were (1) reporting of image quality should be performed and implemented into clinical practice; (2) for interpretation performance, radiologists should use self-performance tests with histopathology feedback, compare their interpretation with expert-reading and use external performance assessments; and (3) radiologists must attend theoretical and hands-on courses before interpreting prostate MRI. Limitations are that the results are expert opinions and not based on systematic reviews or meta-analyses. There was no consensus on outcomes statements of prostate MRI assessment as quality marker. Conclusions: An ESUR and ESUI expert panel showed high agreement (74%) on issues improving prostate MRI quality. Checking and reporting of image quality are mandatory. Prostate radiologists should attend theoretical and hands-on courses, followed by supervised education, and must perform regular performance assessments. Key Points: • Multi-parametric MRI in the diagnostic pathway of prostate cancer has a well-established upfront role in the recently updated European Association of Urology guideline and American Urological Association recommendations. • Suboptimal image acquisition and reporting at an individual level will result in clinicians losing confidence in the technique and returning to the (non-MRI) systematic biopsy pathway. Therefore, it is crucial to establish quality criteria for the acquisition and reporting of mpMRI. • To ensure high-quality prostate MRI, experts consider checking and reporting of image quality mandatory. Prostate radiologists must attend theoretical and hands-on courses, followed by supervised education, and must perform regular self- and external performance assessments.
AB - Objectives: This study aims to define consensus-based criteria for acquiring and reporting prostate MRI and establishing prerequisites for image quality. Methods: A total of 44 leading urologists and urogenital radiologists who are experts in prostate cancer imaging from the European Society of Urogenital Radiology (ESUR) and EAU Section of Urologic Imaging (ESUI) participated in a Delphi consensus process. Panellists completed two rounds of questionnaires with 55 items under three headings: image quality assessment, interpretation and reporting, and radiologists’ experience plus training centres. Of 55 questions, 31 were rated for agreement on a 9-point scale, and 24 were multiple-choice or open. For agreement items, there was consensus agreement with an agreement ≥ 70% (score 7–9) and disagreement of ≤ 15% of the panellists. For the other questions, a consensus was considered with ≥ 50% of votes. Results: Twenty-four out of 31 of agreement items and 11/16 of other questions reached consensus. Agreement statements were (1) reporting of image quality should be performed and implemented into clinical practice; (2) for interpretation performance, radiologists should use self-performance tests with histopathology feedback, compare their interpretation with expert-reading and use external performance assessments; and (3) radiologists must attend theoretical and hands-on courses before interpreting prostate MRI. Limitations are that the results are expert opinions and not based on systematic reviews or meta-analyses. There was no consensus on outcomes statements of prostate MRI assessment as quality marker. Conclusions: An ESUR and ESUI expert panel showed high agreement (74%) on issues improving prostate MRI quality. Checking and reporting of image quality are mandatory. Prostate radiologists should attend theoretical and hands-on courses, followed by supervised education, and must perform regular performance assessments. Key Points: • Multi-parametric MRI in the diagnostic pathway of prostate cancer has a well-established upfront role in the recently updated European Association of Urology guideline and American Urological Association recommendations. • Suboptimal image acquisition and reporting at an individual level will result in clinicians losing confidence in the technique and returning to the (non-MRI) systematic biopsy pathway. Therefore, it is crucial to establish quality criteria for the acquisition and reporting of mpMRI. • To ensure high-quality prostate MRI, experts consider checking and reporting of image quality mandatory. Prostate radiologists must attend theoretical and hands-on courses, followed by supervised education, and must perform regular self- and external performance assessments.
KW - Consensus
KW - Diagnosis
KW - Magnetic resonance imaging
KW - Multi-parametric magnetic resonance imaging
KW - Prostatic neoplasms
UR - http://www.scopus.com/inward/record.url?scp=85085033883&partnerID=8YFLogxK
U2 - 10.1007/s00330-020-06929-z
DO - 10.1007/s00330-020-06929-z
M3 - Journal article
C2 - 32424596
AN - SCOPUS:85085033883
VL - 30
SP - 5404
EP - 5416
JO - European Radiology
JF - European Radiology
SN - 0938-7994
IS - 10