Abstract
| Originalsprog | Engelsk |
|---|---|
| Tidsskrift | Respiratory Medicine |
| Vol/bind | 103 |
| Udgave nummer | 1 |
| Sider (fra-til) | 136-43 |
| Antal sider | 7 |
| ISSN | 0954-6111 |
| DOI | |
| Status | Udgivet - 2008 |
Bibliografisk note
Keywords: Aged; Airway Obstruction; Airway Resistance; Female; Follow-Up Studies; Forced Expiratory Volume; Humans; Lung; Male; Middle Aged; Oscillometry; Plethysmography, Whole Body; Pulmonary Disease, Chronic Obstructive; Sensitivity and Specificity; Spirometry; Statistics, Nonparametric; Tidal Volume; Total Lung CapacityAdgang til dokumentet
Biblioteksadgang?
Tjek tilgængelighed hos det Kgl. BibliotekCitationsformater
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS
I: Respiratory Medicine, Bind 103, Nr. 1, 2008, s. 136-43.
Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › peer review
}
TY - JOUR
T1 - Impulse oscillometry in COPD: identification of measurements related to airway obstruction, airway conductance and lung volumes
AU - Kolsum, Umme
AU - Borrill, Zoë
AU - Roy, Kay
AU - Starkey, Cerys
AU - Vestbo, Jørgen
AU - Houghton, Catherine
AU - Singh, Dave
N1 - Keywords: Aged; Airway Obstruction; Airway Resistance; Female; Follow-Up Studies; Forced Expiratory Volume; Humans; Lung; Male; Middle Aged; Oscillometry; Plethysmography, Whole Body; Pulmonary Disease, Chronic Obstructive; Sensitivity and Specificity; Spirometry; Statistics, Nonparametric; Tidal Volume; Total Lung Capacity
PY - 2008
Y1 - 2008
N2 - BACKGROUND: Impulse oscillometry system (IOS) assesses pulmonary resistance and reactance. We set out to investigate which IOS measurements are related to airflow obstruction, airway conductance and lung volumes in chronic obstructive pulmonary disease (COPD). METHODS: Ninety-four COPD patients were recruited and 58 agreed to follow up after 1 year. IOS measurements (R5, R20, X5 & Fres), body plethysmography (sGaw, FRC, TLC, RV & IC) and spirometry (FEV(1)) were performed. Pearson or Spearman correlation determined the relationships between IOS and other measurements. RESULTS: R5, X5 and Fres were all significantly associated (p<0.05) with FEV(1), sGaw, TLC, RV and IC. However, R20 was not related to any of these measurements except for RV. The strongest associations were observed between FEV(1) and the reactance measurements X5 (r=0.48) and Fres (r=-0.44), and sGaw with X5 (r=0.47) and Fres (r=0.51). The r values for the associations with TLC and IC were all <0.25. There was no statistically significant change in the FEV(1), R5, X5 or Fres after 1 year, but R20 significantly increased over the year. The changes in R5 and R20 did not significantly correlate with the changes in FEV(1). In contrast, X5 changes were significantly related to FEV(1) changes over 1 year (r=-0.27, p=0.05), while for Fres changes there was a trend to statistical significance (p=0.08). CONCLUSIONS: IOS reactance measurements are more closely related than resistance measurements to other pulmonary function measurements in COPD patients. The IOS reactance measurements appear to be indicative of changes in pulmonary compliance caused by airflow obstruction.
AB - BACKGROUND: Impulse oscillometry system (IOS) assesses pulmonary resistance and reactance. We set out to investigate which IOS measurements are related to airflow obstruction, airway conductance and lung volumes in chronic obstructive pulmonary disease (COPD). METHODS: Ninety-four COPD patients were recruited and 58 agreed to follow up after 1 year. IOS measurements (R5, R20, X5 & Fres), body plethysmography (sGaw, FRC, TLC, RV & IC) and spirometry (FEV(1)) were performed. Pearson or Spearman correlation determined the relationships between IOS and other measurements. RESULTS: R5, X5 and Fres were all significantly associated (p<0.05) with FEV(1), sGaw, TLC, RV and IC. However, R20 was not related to any of these measurements except for RV. The strongest associations were observed between FEV(1) and the reactance measurements X5 (r=0.48) and Fres (r=-0.44), and sGaw with X5 (r=0.47) and Fres (r=0.51). The r values for the associations with TLC and IC were all <0.25. There was no statistically significant change in the FEV(1), R5, X5 or Fres after 1 year, but R20 significantly increased over the year. The changes in R5 and R20 did not significantly correlate with the changes in FEV(1). In contrast, X5 changes were significantly related to FEV(1) changes over 1 year (r=-0.27, p=0.05), while for Fres changes there was a trend to statistical significance (p=0.08). CONCLUSIONS: IOS reactance measurements are more closely related than resistance measurements to other pulmonary function measurements in COPD patients. The IOS reactance measurements appear to be indicative of changes in pulmonary compliance caused by airflow obstruction.
U2 - 10.1016/j.rmed.2008.07.014
DO - 10.1016/j.rmed.2008.07.014
M3 - Journal article
C2 - 18760576
SN - 0954-6111
VL - 103
SP - 136
EP - 143
JO - Respiratory Medicine
JF - Respiratory Medicine
IS - 1
ER -