In Vivo Super Resolution Ultrasound Imaging using the Erythrocytes - SURE

Jørgen Arendt Jensen, Mikkel Schou, Sofie Bech Andersen, Borislav G. Tomov, Stinne Byrholdt Søgaard, Charlotte Mehlin Sørensen, Michael Bachmann Nielsen, Carsten Gundlach, Hans Martin Kjer, Anders Bjorholm Dahl, Matthias Bo Stuart

Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

6 Citationer (Scopus)
12 Downloads (Pure)

Abstract

Current super resolution imaging is conducted using ultrasound contrast agents, where a sparse distribution of bubbles must be employed to separate individual targets. The sparse targets make the acquisition time long in the range of 1 to 10 minutes, and therefore demands an accurate motion correction over a long time. The employment of a contrast agent also lowers MI to below 0.2 to not disrupt the bubbles, with a corresponding lower signal-to-noise ratio in the images. A new method, SURE (SUper Resolution ultrasound imaging using Erythrocytes), where erythrocytes are used as targets, is suggested to alleviate these problems. Perfused tissues contain an abundance of targets, and the full clinical pressure range can be used. It is hypothesized that super resolution imaging below the diffraction limit can be attained in seconds using SURE imaging. A SURE processing pipeline was developed with modules for beamforming, tissue motion estimation, alignment, singular value decomposition for echo canceling, and subsequent peak detection in the speckle pattern. The detected peaks were summed in a high-resolution image for yielding the SURE image. Data were acquired using a 10 MHz linear array GE L10-18i probe (150 μm wavelength) and a Verasonics Vantage 256 scanner. A synthetic aperture scan sequence with 12 emissions was employed at a pulse repetition frequency of 5 kHz for a 417 Hz frame rate. Kidneys of Sprague-Dawley rats were scanned for 24 seconds and RF data stored for off-line processing. The excised kidneys were micro-CT scanned for 11 hours for generating reference maps of the vasculature with a voxel size of 21 μm. SURE images revealed vessels with sizes down to 50 μm. Fourier ring correlations between independent images measured for 12 s revealed a resolution between 25 to 49 μm, demonstrating the super resolution capability of the method. The SURE images are obtained in 1 to 12 seconds, demand no injection of intravenous contrast agents, and can use the full pressure and intensity range allowed in medical ultrasound, making the method easily adaptable to clinical use.

OriginalsprogEngelsk
TidsskriftIEEE International Ultrasonics Symposium, IUS
Vol/bind2022
Sider (fra-til)1-4
ISSN1948-5719
DOI
StatusUdgivet - 2022
Begivenhed2022 IEEE International Ultrasonics Symposium, IUS 2022 - Venice, Italien
Varighed: 10 okt. 202213 okt. 2022

Konference

Konference2022 IEEE International Ultrasonics Symposium, IUS 2022
Land/OmrådeItalien
ByVenice
Periode10/10/202213/10/2022
SponsorIEEE, IEEE Ultrasonics, Ferroelectrics, and Frequency Control Society (UFFC)

Bibliografisk note

Funding Information:
This work was financially supported by ERC synergy grant 854796 - SURE from the European Research Council.

Publisher Copyright:
© 2022 IEEE.

Citationsformater