TY - JOUR
T1 - Incidence and risk factors for first and recurrent ICD shock therapy in patients with an implantable cardioverter defibrillator
AU - Frodi, Diana My
AU - Diederichsen, Søren Zöga
AU - Xing, Lucas Yixi
AU - Spona, Daniel Camillo
AU - Jacobsen, Peter Karl
AU - Risum, Niels
AU - Svendsen, Jesper Hastrup
N1 - © 2024. The Author(s).
PY - 2024/8/21
Y1 - 2024/8/21
N2 - BACKGROUND: Advances in medical treatment and outcomes in implantable cardioverter-defibrillator (ICD) recipients incentivize a need for improved candidate selection and identification of risk factors for ICD therapy. We examined contemporary rates of and risk factors for ICD therapy.METHODS: Patients with ICD for primary (PP) or secondary prevention (SP), implanted between January 2010 and December 2020, were followed for appropriate and inappropriate incident and recurrent shock.RESULTS: Overall, 2998 patients (mean age 61.8 ± 12.7 years, 20% female, 73% ICD carriers, and 47.1% SP) were analyzed with a median follow-up of 4.3 (interquartile range (IQR) 2.1-7.4) years. A total of 426/2998 (14.2%) patients had shock; 364/2998 (12.1%) had appropriate and 82/2998 (2.7%) inappropriate shock, with annualized event rates of 2.34 (2.11-2.59) and 0.49 (0.39-0.61) per 100 person-years, respectively. Of those with shock, 133/364 (36.5%) experienced recurrent appropriate shock and 8/364 (2.2%) received recurrent inappropriate shock, with event rates of 10.57 (8.85-12.53) and 0.46 (0.20-0.92), respectively. In multivariable analyses, female sex was associated with a reduced risk of incident appropriate shock (hazard ratio 0.69 [95% confidence interval 0.52; 0.91]). Of other variables, only revascularization status was associated with recurrent appropriate shock in PP, and CRT-D with recurrent appropriate shock in the overall cohort.CONCLUSION: One in eight ICD recipients received appropriate shock 2-7 years after guideline-directed implantation. More than one-third of patients with a first shock experienced recurrent shock. Few clinical variables showed potential in predicting shocks, illustrating a need for more advanced tools to select candidates for implantation.
AB - BACKGROUND: Advances in medical treatment and outcomes in implantable cardioverter-defibrillator (ICD) recipients incentivize a need for improved candidate selection and identification of risk factors for ICD therapy. We examined contemporary rates of and risk factors for ICD therapy.METHODS: Patients with ICD for primary (PP) or secondary prevention (SP), implanted between January 2010 and December 2020, were followed for appropriate and inappropriate incident and recurrent shock.RESULTS: Overall, 2998 patients (mean age 61.8 ± 12.7 years, 20% female, 73% ICD carriers, and 47.1% SP) were analyzed with a median follow-up of 4.3 (interquartile range (IQR) 2.1-7.4) years. A total of 426/2998 (14.2%) patients had shock; 364/2998 (12.1%) had appropriate and 82/2998 (2.7%) inappropriate shock, with annualized event rates of 2.34 (2.11-2.59) and 0.49 (0.39-0.61) per 100 person-years, respectively. Of those with shock, 133/364 (36.5%) experienced recurrent appropriate shock and 8/364 (2.2%) received recurrent inappropriate shock, with event rates of 10.57 (8.85-12.53) and 0.46 (0.20-0.92), respectively. In multivariable analyses, female sex was associated with a reduced risk of incident appropriate shock (hazard ratio 0.69 [95% confidence interval 0.52; 0.91]). Of other variables, only revascularization status was associated with recurrent appropriate shock in PP, and CRT-D with recurrent appropriate shock in the overall cohort.CONCLUSION: One in eight ICD recipients received appropriate shock 2-7 years after guideline-directed implantation. More than one-third of patients with a first shock experienced recurrent shock. Few clinical variables showed potential in predicting shocks, illustrating a need for more advanced tools to select candidates for implantation.
U2 - 10.1007/s10840-024-01873-0
DO - 10.1007/s10840-024-01873-0
M3 - Journal article
C2 - 39168942
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
SN - 1383-875X
ER -