TY - JOUR
T1 - Nocturnal pulse wave amplitude attenuations are associated with long-term cardiovascular events
AU - Shahrbabaki, Sobhan Salari
AU - Linz, Dominik
AU - Baumert, Mathias
N1 - Publisher Copyright:
© 2023 The Author(s)
PY - 2023
Y1 - 2023
N2 - Objectives: Photoplethysmography (PPG) is an established technology for detecting pulse rate and pulse wave irregularities. However, whether temporal variations in pulse wave amplitudes, reflecting a combination of acute hemodynamic or autonomic responses to changes in overall vascular function, carry prognostic information remains unclear. To quantify nocturnal temporal pulse wave amplitude (PWA) attenuations and evaluate its association with long-term cardiovascular (CV) events in a large, racially diverse sample of men and women. Methods: Temporal PWA attenuations were determined based on the slopes between the upper and lower envelopes of PPGs derived from overnight polysomnography of 1957 participants (899 men, 1058 women, mean age 68.2 ± 9.1 years) of the Multi-Ethnic Study of Atherosclerosis. The nocturnal PWA attenuation index was defined as the cumulative duration of all PWA attenuation events relative to total sleep duration. Results: Nocturnal PWA attenuation index was greater in men than in women by almost 13% (16.3 ± 8.9% vs. 14.4 ± 7.9%, p < 0.001). The nocturnal PWA attenuation index was highest in Chinese-American participants (17.9 ± 9.2%) and lowest in African-Americans (13.5 ± 8.1%). During a median follow-up of 4.9 years, 94 CV events occurred. In multivariable Cox proportional hazard analysis adjusted for typical confounders, the nocturnal PWA attenuation index <15.2% was associated with CV events (HR = 1.58 [1.02–2.45], p = 0.042). Conclusions: Nocturnal PWA attenuation index is inversely associated with the risk of CV events, particularly in men and African-Americans. The PPG-derived nocturnal PWA attenuation index could be simply obtained from smart wearable consumer devices and may provide a low-cost, accessible and scalable CV risk marker.
AB - Objectives: Photoplethysmography (PPG) is an established technology for detecting pulse rate and pulse wave irregularities. However, whether temporal variations in pulse wave amplitudes, reflecting a combination of acute hemodynamic or autonomic responses to changes in overall vascular function, carry prognostic information remains unclear. To quantify nocturnal temporal pulse wave amplitude (PWA) attenuations and evaluate its association with long-term cardiovascular (CV) events in a large, racially diverse sample of men and women. Methods: Temporal PWA attenuations were determined based on the slopes between the upper and lower envelopes of PPGs derived from overnight polysomnography of 1957 participants (899 men, 1058 women, mean age 68.2 ± 9.1 years) of the Multi-Ethnic Study of Atherosclerosis. The nocturnal PWA attenuation index was defined as the cumulative duration of all PWA attenuation events relative to total sleep duration. Results: Nocturnal PWA attenuation index was greater in men than in women by almost 13% (16.3 ± 8.9% vs. 14.4 ± 7.9%, p < 0.001). The nocturnal PWA attenuation index was highest in Chinese-American participants (17.9 ± 9.2%) and lowest in African-Americans (13.5 ± 8.1%). During a median follow-up of 4.9 years, 94 CV events occurred. In multivariable Cox proportional hazard analysis adjusted for typical confounders, the nocturnal PWA attenuation index <15.2% was associated with CV events (HR = 1.58 [1.02–2.45], p = 0.042). Conclusions: Nocturnal PWA attenuation index is inversely associated with the risk of CV events, particularly in men and African-Americans. The PPG-derived nocturnal PWA attenuation index could be simply obtained from smart wearable consumer devices and may provide a low-cost, accessible and scalable CV risk marker.
KW - Cardiovascular disease
KW - Photoplethysmography
KW - Pulse wave
KW - Sleep
UR - http://www.scopus.com/inward/record.url?scp=85160783255&partnerID=8YFLogxK
U2 - 10.1016/j.ijcard.2023.05.047
DO - 10.1016/j.ijcard.2023.05.047
M3 - Journal article
C2 - 37257516
AN - SCOPUS:85160783255
VL - 385
SP - 55
EP - 61
JO - International Journal of Cardiology
JF - International Journal of Cardiology
SN - 0167-5273
ER -