TY - JOUR
T1 - Occlusion Pressure of the Thoracic Duct in Fontan Patients With Lymphatic Failure
T2 - Does Dilatation Challenge Contractility?
AU - Savla, Jill J.
AU - Kelly, Benjamin
AU - Krogh, Emil
AU - Smith, Christopher L.
AU - Krishnamurthy, Ganesh
AU - Glatz, Andrew C.
AU - DeWitt, Aaron G.
AU - Pinto, Erin M.
AU - Ravishankar, Chitra
AU - Gillespie, Matthew J.
AU - O’Byrne, Michael L.
AU - Escobar, Fernando A.
AU - Rome, Jonathan J.
AU - Hjortdal, Vibeke
AU - Dori, Yoav
N1 - Publisher Copyright:
© The Author(s) 2022.
PY - 2022
Y1 - 2022
N2 - Background: The Fontan circulation challenges the lymphatic system. Increasing production of lymphatic fluid and impeding lymphatic return, increased venous pressure may cause lymphatic dilatation and decrease lymphatic contractility. In-vitro studies have reported a lymphatic diameter-tension curve, with increasing passive stretch affecting the intrinsic contractile properties of each thoracic duct segment. We aimed to describe thoracic duct occlusion pressure and asses if thoracic duct dilation impairs contractility in individuals with a Fontan circulation and lymphatic failure. Methods: Central venous pressure and thoracic duct measurements were retrospectively collected from 31 individuals with a Fontan circulation. Thoracic duct occlusion pressure was assessed during a period of external manual compression and used as an indicator of lymphatic vessel contractility. Measurements of pressure were correlated with measurements of the thoracic duct diameter in images obtained by dynamic contrast-enhanced MR lymphangiography. Results: The average central venous pressure and average pressure of the thoracic duct were 17 mm Hg. During manual occlusion, the thoracic duct pressure significantly increased to 32 mm Hg. The average thoracic duct diameter was 3.3 mm. Thoracic duct diameter correlated closely with the central venous pressure. The rise in pressure following manual occlusion showed an inverse correlation with the diameter of the thoracic duct. Conclusion: Higher central venous pressures are associated with increasing diameters of the thoracic duct. When challenged by manual occlusion, dilated thoracic ducts display a decreased ability to increase pressure. Dilatation and a resulting decreased contractility may partly explain the challenged lymphatic system in individuals with a Fontan circulation.
AB - Background: The Fontan circulation challenges the lymphatic system. Increasing production of lymphatic fluid and impeding lymphatic return, increased venous pressure may cause lymphatic dilatation and decrease lymphatic contractility. In-vitro studies have reported a lymphatic diameter-tension curve, with increasing passive stretch affecting the intrinsic contractile properties of each thoracic duct segment. We aimed to describe thoracic duct occlusion pressure and asses if thoracic duct dilation impairs contractility in individuals with a Fontan circulation and lymphatic failure. Methods: Central venous pressure and thoracic duct measurements were retrospectively collected from 31 individuals with a Fontan circulation. Thoracic duct occlusion pressure was assessed during a period of external manual compression and used as an indicator of lymphatic vessel contractility. Measurements of pressure were correlated with measurements of the thoracic duct diameter in images obtained by dynamic contrast-enhanced MR lymphangiography. Results: The average central venous pressure and average pressure of the thoracic duct were 17 mm Hg. During manual occlusion, the thoracic duct pressure significantly increased to 32 mm Hg. The average thoracic duct diameter was 3.3 mm. Thoracic duct diameter correlated closely with the central venous pressure. The rise in pressure following manual occlusion showed an inverse correlation with the diameter of the thoracic duct. Conclusion: Higher central venous pressures are associated with increasing diameters of the thoracic duct. When challenged by manual occlusion, dilated thoracic ducts display a decreased ability to increase pressure. Dilatation and a resulting decreased contractility may partly explain the challenged lymphatic system in individuals with a Fontan circulation.
KW - cardiac catheterization/intervention
KW - CHD
KW - lymphatics
KW - magnetic resonance imaging
KW - univentricular heart
U2 - 10.1177/21501351221119394
DO - 10.1177/21501351221119394
M3 - Journal article
C2 - 36300263
AN - SCOPUS:85147477727
VL - 13
SP - 737
EP - 744
JO - World journal for pediatric & congenital heart surgery
JF - World journal for pediatric & congenital heart surgery
SN - 2150-1351
IS - 6
ER -