T1 - Region specific optimization of continuous linear attenuation coefficients based on UTE (RESOLUTE)
T2 - application to PET/MR brain imaging
AU - Ladefoged, Claes N
AU - Benoit, Didier
AU - Law, Ian
AU - Holm, Søren
AU - Kjær, Andreas
AU - Højgaard, Liselotte
AU - Hansen, Adam E
AU - Andersen, Flemming L
PY - 2015/10/21
Y1 - 2015/10/21
N2 - The reconstruction of PET brain data in a PET/MR hybrid scanner is challenging in the absence of transmission sources, where MR images are used for MR-based attenuation correction (MR-AC). The main challenge of MR-AC is to separate bone and air, as neither have a signal in traditional MR images, and to assign the correct linear attenuation coefficient to bone. The ultra-short echo time (UTE) MR sequence was proposed as a basis for MR-AC as this sequence shows a small signal in bone. The purpose of this study was to develop a new clinically feasible MR-AC method with patient specific continuous-valued linear attenuation coefficients in bone that provides accurate reconstructed PET image data. A total of 164 [(18)F]FDG PET/MR patients were included in this study, of which 10 were used for training. MR-AC was based on either standard CT (reference), UTE or our method (RESOLUTE). The reconstructed PET images were evaluated in the whole brain, as well as regionally in the brain using a ROI-based analysis. Our method segments air, brain, cerebral spinal fluid, and soft tissue voxels on the unprocessed UTE TE images, and uses a mapping of R(*)2 values to CT Hounsfield Units (HU) to measure the density in bone voxels. The average error of our method in the brain was 0.1% and less than 1.2% in any region of the brain. On average 95% of the brain was within ±10% of PETCT, compared to 72% when using UTE. The proposed method is clinically feasible, reducing both the global and local errors on the reconstructed PET images, as well as limiting the number and extent of the outliers.
AB - The reconstruction of PET brain data in a PET/MR hybrid scanner is challenging in the absence of transmission sources, where MR images are used for MR-based attenuation correction (MR-AC). The main challenge of MR-AC is to separate bone and air, as neither have a signal in traditional MR images, and to assign the correct linear attenuation coefficient to bone. The ultra-short echo time (UTE) MR sequence was proposed as a basis for MR-AC as this sequence shows a small signal in bone. The purpose of this study was to develop a new clinically feasible MR-AC method with patient specific continuous-valued linear attenuation coefficients in bone that provides accurate reconstructed PET image data. A total of 164 [(18)F]FDG PET/MR patients were included in this study, of which 10 were used for training. MR-AC was based on either standard CT (reference), UTE or our method (RESOLUTE). The reconstructed PET images were evaluated in the whole brain, as well as regionally in the brain using a ROI-based analysis. Our method segments air, brain, cerebral spinal fluid, and soft tissue voxels on the unprocessed UTE TE images, and uses a mapping of R(*)2 values to CT Hounsfield Units (HU) to measure the density in bone voxels. The average error of our method in the brain was 0.1% and less than 1.2% in any region of the brain. On average 95% of the brain was within ±10% of PETCT, compared to 72% when using UTE. The proposed method is clinically feasible, reducing both the global and local errors on the reconstructed PET images, as well as limiting the number and extent of the outliers.
KW - Adipose Tissue
KW - Aged
KW - Bone and Bones
KW - Brain
KW - Brain Diseases
KW - Cerebrospinal Fluid
KW - Female
KW - Fluorodeoxyglucose F18
KW - Humans
KW - Image Processing, Computer-Assisted
KW - Magnetic Resonance Imaging
KW - Male
KW - Neuroimaging
KW - Positron-Emission Tomography
KW - Radiopharmaceuticals
KW - Retrospective Studies
KW - Tomography, Emission-Computed, Single-Photon
KW - Tomography, X-Ray Computed
U2 - 10.1088/0031-9155/60/20/8047
DO - 10.1088/0031-9155/60/20/8047
M3 - Journal article
C2 - 26422177
VL - 60
SP - 8047
EP - 8065
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
SN - 0031-9155
IS - 20
ER -