Abstract
Originalsprog | Engelsk |
---|---|
Tidsskrift | American Journal of Cardiology |
Vol/bind | 103 |
Udgave nummer | 8 |
Sider (fra-til) | 1083-8 |
Antal sider | 5 |
ISSN | 0002-9149 |
DOI | |
Status | Udgivet - 2009 |
Bibliografisk note
Keywords: Aged; Angioplasty, Transluminal, Percutaneous Coronary; Coronary Restenosis; Diabetes Complications; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Paclitaxel; Sirolimus; Ultrasonography, InterventionalAdgang til dokumentet
Citationsformater
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS
Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus. / Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S; Christiansen, Evald Hoej; Hansen, Knud Noerregaard; Galloe, Anders; Kelbaek, Henning; Lassen, Jens Flensted; Thuesen, Leif; Thayssen, Per.
I: American Journal of Cardiology, Bind 103, Nr. 8, 2009, s. 1083-8.Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › peer review
}
TY - JOUR
T1 - Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus
AU - Jensen, Lisette Okkels
AU - Maeng, Michael
AU - Mintz, Gary S
AU - Christiansen, Evald Hoej
AU - Hansen, Knud Noerregaard
AU - Galloe, Anders
AU - Kelbaek, Henning
AU - Lassen, Jens Flensted
AU - Thuesen, Leif
AU - Thayssen, Per
N1 - Keywords: Aged; Angioplasty, Transluminal, Percutaneous Coronary; Coronary Restenosis; Diabetes Complications; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Paclitaxel; Sirolimus; Ultrasonography, Interventional
PY - 2009
Y1 - 2009
N2 - Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston Scientific, Maple Grove, Minnesota) stents in diabetic patients. Seventy-four diabetic patients were randomly assigned to Cypher or Taxus stent implantation. Intravascular ultrasound of 5-mm long segments immediately proximal and distal to the stent was performed after the procedure and at the 8-month follow-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2); p = 0.097; proximal, 8.1 +/- 2.7 to 8.7 +/- 2.9 mm(2); p = 0.006) without remodeling (change in EEM) in the Taxus group. Conversely, there were no significant changes in reference-segment EEM or plaque areas in the Cypher group. In conclusion, in diabetic patients, Taxus stent implantation was associated with increased (1) peri-stent EEM volume and peri-stent plaque, and (2) stent edge plaque progression accompanied by lumen reduction without remodeling. These findings were not seen in Cypher stents.
AB - Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston Scientific, Maple Grove, Minnesota) stents in diabetic patients. Seventy-four diabetic patients were randomly assigned to Cypher or Taxus stent implantation. Intravascular ultrasound of 5-mm long segments immediately proximal and distal to the stent was performed after the procedure and at the 8-month follow-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2); p = 0.097; proximal, 8.1 +/- 2.7 to 8.7 +/- 2.9 mm(2); p = 0.006) without remodeling (change in EEM) in the Taxus group. Conversely, there were no significant changes in reference-segment EEM or plaque areas in the Cypher group. In conclusion, in diabetic patients, Taxus stent implantation was associated with increased (1) peri-stent EEM volume and peri-stent plaque, and (2) stent edge plaque progression accompanied by lumen reduction without remodeling. These findings were not seen in Cypher stents.
U2 - 10.1016/j.amjcard.2008.12.035
DO - 10.1016/j.amjcard.2008.12.035
M3 - Journal article
C2 - 19361594
VL - 103
SP - 1083
EP - 1088
JO - Am. J. Cardiol.
JF - Am. J. Cardiol.
SN - 0002-9149
IS - 8
ER -