TY - JOUR
T1 - The impact of co-morbidity burden on appropriate implantable cardioverter defibrillator therapy and all-cause mortality
T2 - insight from Danish nationwide clinical registers
AU - Ruwald, Anne Christine
AU - Vinther, Michael
AU - Gislason, Gunnar H
AU - Johansen, Jens Brock
AU - Nielsen, Jens Cosedis
AU - Petersen, Helen Høgh
AU - Riahi, Sam
AU - Jons, Christian
N1 - © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.
PY - 2017/3
Y1 - 2017/3
N2 - AIMS: In a nationwide cohort of primary (PP-ICD) and secondary prevention (SP-ICD) implantable cardioverter defibrillator (ICD) patients, we aimed to investigate the association between co-morbidity burden and risk of appropriate ICD therapy and mortality.METHODS AND RESULTS: We identified all patients >18 years, implanted with first-time PP-ICD (n = 1873) or SP-ICD (n = 2461) in Denmark from 2007 to 2012. Co-morbidity was identified in administrative registers of hospitalization and drug prescription from pharmacies. Co-morbidity burden was defined as the number of pre-existing non-ICD indication-related co-morbidities including atrial fibrillation, diabetes, chronic obstructive pulmonary disease, chronic renal disease, liver disease, cancer, chronic psychiatric disease, and peripheral and/or cerebrovascular disease, and divided into four groups (co-morbidity burden 0, 1, 2, and ≥3). Through Cox models, we assessed the impact of co-morbidity burden on appropriate ICD therapy and mortality. Increasing co-morbidity burden was not associated with increased risk of appropriate therapy, irrespective of implant indication [all hazard ratios (HRs) 1.0-1.4, P = NS]. Using no co-morbidities as reference, increasing co-morbidity burden was associated with increased mortality risk in PP-ICD patients (co-morbidity burden 1, HR 2.1; comorbidity burden 2, HR 3.7; co-morbidity burden ≥3, HR 6.6) (all P < 0.001) and SP-ICD patients (co-morbidity burden 1, HR 2.2; co-morbidity burden 2, HR 3.8; co-morbidity burden ≥3, HR 5.8). With increasing co-morbidity burden, an increasing frequency of patients died without having utilized their device, with 72% PP-ICD and 45% SP-ICD patients with co-morbidity burden ≥3 dying without prior appropriate ICD therapy.CONCLUSION: Increasing co-morbidity burden was not associated with increased risk of appropriate ICD therapy. With increasing co-morbidity burden, mortality increased, and a higher proportion of patients died, without ever having utilized their device.
AB - AIMS: In a nationwide cohort of primary (PP-ICD) and secondary prevention (SP-ICD) implantable cardioverter defibrillator (ICD) patients, we aimed to investigate the association between co-morbidity burden and risk of appropriate ICD therapy and mortality.METHODS AND RESULTS: We identified all patients >18 years, implanted with first-time PP-ICD (n = 1873) or SP-ICD (n = 2461) in Denmark from 2007 to 2012. Co-morbidity was identified in administrative registers of hospitalization and drug prescription from pharmacies. Co-morbidity burden was defined as the number of pre-existing non-ICD indication-related co-morbidities including atrial fibrillation, diabetes, chronic obstructive pulmonary disease, chronic renal disease, liver disease, cancer, chronic psychiatric disease, and peripheral and/or cerebrovascular disease, and divided into four groups (co-morbidity burden 0, 1, 2, and ≥3). Through Cox models, we assessed the impact of co-morbidity burden on appropriate ICD therapy and mortality. Increasing co-morbidity burden was not associated with increased risk of appropriate therapy, irrespective of implant indication [all hazard ratios (HRs) 1.0-1.4, P = NS]. Using no co-morbidities as reference, increasing co-morbidity burden was associated with increased mortality risk in PP-ICD patients (co-morbidity burden 1, HR 2.1; comorbidity burden 2, HR 3.7; co-morbidity burden ≥3, HR 6.6) (all P < 0.001) and SP-ICD patients (co-morbidity burden 1, HR 2.2; co-morbidity burden 2, HR 3.8; co-morbidity burden ≥3, HR 5.8). With increasing co-morbidity burden, an increasing frequency of patients died without having utilized their device, with 72% PP-ICD and 45% SP-ICD patients with co-morbidity burden ≥3 dying without prior appropriate ICD therapy.CONCLUSION: Increasing co-morbidity burden was not associated with increased risk of appropriate ICD therapy. With increasing co-morbidity burden, mortality increased, and a higher proportion of patients died, without ever having utilized their device.
KW - Aged
KW - Atrial Fibrillation/epidemiology
KW - Cerebrovascular Disorders/epidemiology
KW - Cohort Studies
KW - Comorbidity
KW - Death, Sudden, Cardiac/epidemiology
KW - Defibrillators, Implantable
KW - Denmark/epidemiology
KW - Diabetes Mellitus/epidemiology
KW - Female
KW - Humans
KW - Liver Diseases/epidemiology
KW - Male
KW - Mental Disorders/epidemiology
KW - Middle Aged
KW - Neoplasms/epidemiology
KW - Peripheral Vascular Diseases/epidemiology
KW - Primary Prevention
KW - Proportional Hazards Models
KW - Pulmonary Disease, Chronic Obstructive/epidemiology
KW - Registries
KW - Renal Insufficiency, Chronic/epidemiology
KW - Retrospective Studies
KW - Secondary Prevention
U2 - 10.1002/ejhf.685
DO - 10.1002/ejhf.685
M3 - Journal article
C2 - 27905161
VL - 19
SP - 377
EP - 386
JO - European Journal of Heart Failure
JF - European Journal of Heart Failure
SN - 1567-4215
IS - 3
ER -