The use of double-balloon enteroscopy in retrieving mucosal biopsies from the entire human gastrointestinal tract

Nicolai Alexander Rhee, Peter Vilmann, Hazem Hassan, Jakob Westergren Hendel, Jens Juul Holst, Tina Vilsbøll, Filip Krag Knop

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

11 Citationer (Scopus)

Abstract

OBJECTIVE: The aim of this explorative study was to evaluate double-balloon enteroscopy (DBE) as a new tool for collecting mucosal biopsies from well-defined parts of the entire small and large bowel in patients with type 2 diabetes and in matched healthy subjects.

MATERIAL AND METHODS: Twelve subjects with type 2 diabetes and 12 body mass index and age-matched healthy subjects underwent anterograde and retrograde DBE under nurse-administered propofol sedation on two separate days. We attempted to collect two mucosal biopsies from every 30 cm from pylorus to rectum.

RESULTS: A mean of 21 biopsy sites were sampled in the diabetic group versus 25 in the healthy group. In 4 out of 24 patients (2 [17%] from each group) sampling from the entire gastrointestinal system was possible. Mean depth of maximal insertion (anterograde) was 478 ± 32 cm in patients with type 2 diabetes versus 465 ± 44 cm in healthy subjects (p = 0.81) and with retrograde access 230 ± 36 cm (type 2 diabetes) versus 207 ± 26 cm (healthy subjects).

CONCLUSIONS: DBE is a minimally invasive way of collecting fresh biopsies from the entire gastrointestinal tract and, thus provides research and clinical communities with a new possibility to access hitherto unexplored human anatomy and physiology.

OriginalsprogEngelsk
TidsskriftScandinavian Journal of Gastroenterology
Vol/bind49
Udgave nummer9
Sider (fra-til)1143-1149
Antal sider7
ISSN0036-5521
DOI
StatusUdgivet - sep. 2014