TY - JOUR
T1 - Ultrasound assessment of degenerative muscle sarcopenia
T2 - The University of Barcelona ultrasound scoring system for sarcopenia
AU - Möller Parera, Ingrid
AU - Miguel, Maribel
AU - Blasi, Joan
AU - Piccaso, Riccardo
AU - Hammer, Hilde Berner
AU - Ortiz-Sagrista, Juan
AU - Zaottini, Federico
AU - Martinoli, Carlo
AU - Terslev, Lene
N1 - Publisher Copyright:
© 2023 Authors. All rights reserved.
PY - 2023
Y1 - 2023
N2 - Aim This study aimed to (1) determine the intraobserver and interobserver reliability of ultrasonographic measurement of muscle thickness (MT) and cross-sectional area (CSA) of the rectus femoris and biceps brachii, correlating these values with manual measurements on dissected cadavers and (2) develop the first semiquantitative musculoskeletal ultrasound (MSUS) scoring system of muscle morphology in sarcopenia and assess its intraobserver and interobserver reliability. In addition, the MSUS morphology score was compared with the corresponding histological images to verify concurrent validity. Methods Ten cryopreserved limbs of 10 cadavers aged 68-91 years were evaluated. The MSUS scoring system was based on the severity of muscle degeneration on a 3-point qualitative scale: grade 1 (normal), grade 2 (moderate changes) and grade 3 (severe changes). Reliability was assessed with intraclass correlation coefficient (ICC) for the MT and CSA and with Cohen's kappa coefficients (κ) for the MSUS scoring system. Concurrent validity was analysed with ICC. Results The results showed excellent intraobserver and interobserver reliability for both the MSUS evaluation of MT and CSA (ICC ≥0.93). The MSUS scoring system showed excellent intraobserver reliability (κ=1.0) and very good interobserver reliability (κ=0.85). There was also a high intra- and inter-observer reliability for the histological scorings (ĸ ≥0.85 and mean ĸ =0.70, respectively), as well as high reliability between the histology and MSUS scoring systems (ICC=0.92). All results were statistically significant (p≤0.001). Conclusion MSUS measures of MT and CSA and the novel MSUS scoring system for degenerative muscle changes in sarcopenia was found to be reliable and strongly associated with histological findings.
AB - Aim This study aimed to (1) determine the intraobserver and interobserver reliability of ultrasonographic measurement of muscle thickness (MT) and cross-sectional area (CSA) of the rectus femoris and biceps brachii, correlating these values with manual measurements on dissected cadavers and (2) develop the first semiquantitative musculoskeletal ultrasound (MSUS) scoring system of muscle morphology in sarcopenia and assess its intraobserver and interobserver reliability. In addition, the MSUS morphology score was compared with the corresponding histological images to verify concurrent validity. Methods Ten cryopreserved limbs of 10 cadavers aged 68-91 years were evaluated. The MSUS scoring system was based on the severity of muscle degeneration on a 3-point qualitative scale: grade 1 (normal), grade 2 (moderate changes) and grade 3 (severe changes). Reliability was assessed with intraclass correlation coefficient (ICC) for the MT and CSA and with Cohen's kappa coefficients (κ) for the MSUS scoring system. Concurrent validity was analysed with ICC. Results The results showed excellent intraobserver and interobserver reliability for both the MSUS evaluation of MT and CSA (ICC ≥0.93). The MSUS scoring system showed excellent intraobserver reliability (κ=1.0) and very good interobserver reliability (κ=0.85). There was also a high intra- and inter-observer reliability for the histological scorings (ĸ ≥0.85 and mean ĸ =0.70, respectively), as well as high reliability between the histology and MSUS scoring systems (ICC=0.92). All results were statistically significant (p≤0.001). Conclusion MSUS measures of MT and CSA and the novel MSUS scoring system for degenerative muscle changes in sarcopenia was found to be reliable and strongly associated with histological findings.
KW - Autoimmunity
KW - Fibroblasts
KW - Ultrasonography
U2 - 10.1136/rmdopen-2022-002779
DO - 10.1136/rmdopen-2022-002779
M3 - Journal article
C2 - 36707106
AN - SCOPUS:85147089112
VL - 9
JO - RMD Open
JF - RMD Open
SN - 2056-5933
IS - 1
M1 - e002779
ER -