Skip to main navigation Skip to search Skip to main content

Accuracy and sources of error for an angle independent volume flow estimator

  • Jonas Jensen*
  • , Jacob Bjerring Olesen
  • , Peter Møller Hansen
  • , Michael Bachmann Nielsen
  • , Jørgen Arendt Jensen
  • *Corresponding author for this work

Research output: Chapter in Book/Report/Conference proceeding › Article in proceedings › Research › peer-review

Abstract

This paper investigates sources of error for a vector velocity volume flow estimator. Quantification of the estimator's accuracy is performed theoretically and investigated in vivo. Womersley's model for pulsatile flow is used to simulate velocity profiles and calculate volume flow errors in cases of elliptical vessels and not placing the transducer at the vessel center. Simulations show, i.e., that volume flow is underestimated with 5 %, when the transducer is placed 15 % from the vessel center. Twenty patients with arteriovenous fistulas for hemodialysis are scanned in a clinical study. A BK Medical UltraView 800 ultrasound scanner with a 9 MHz linear array transducer is used to obtain Vector Flow Imaging sequences of a superficial part of the fistulas. Cross-sectional diameters of each fistula are measured on B-mode images by rotating the scan plane 90 degrees. The major axis of the fistulas was on average 8.6 % larger than the minor axis, so elliptic dimensions should be taken into account in volume flow estimation. The ultrasound beam was on average 1.5 ± 0.8 mm off-axis, corresponding to 28.5 ± 11.3 % of the major semi-axis of a fistula, and this could result in 15 % underestimated volume flow according to the simulation. Volume flow estimates were corrected for the beam being off-axis, but was not able to significantly decrease the error relative to measurements with the reference method.

Original languageEnglish
Title of host publicationIEEE International Ultrasonics Symposium, IUS
Number of pages4
PublisherIEEE Computer Society Press
Publication date20 Oct 2014
Pages1714-1717
Article number6932079
ISBN (Electronic)9781479970490
DOIs
Publication statusPublished - 20 Oct 2014
Event2014 IEEE International Ultrasonics Symposium, IUS 2014 - Chicago, United States
Duration: 3 Sept 2014 → 6 Sept 2014

Conference

Conference2014 IEEE International Ultrasonics Symposium, IUS 2014
Country/TerritoryUnited States
CityChicago
Period03/09/2014 → 06/09/2014
SeriesIEEE International Ultrasonics Symposium, IUS
ISSN1948-5719

Bibliographical note

Publisher Copyright:
© 2014 IEEE.