Instrumental and theoretical advancements in pulsed elution-LC × LC: Investigation of pulse parameters and application to wastewater effluent

Oskar Munk Kronik*, Jan H. Christensen, Nikoline Juul Nielsen

*Corresponding author for this work

Research output: Contribution to journalJournal articleResearchpeer-review

1 Citation (Scopus)
8 Downloads (Pure)

Abstract

Due to the decoupling of the first (1D) and second (2D) dimension in pulsed elution-LC × LC (PE-LC × LC), method development is more flexible and straightforward compared to fast comprehensive LC × LC where the dependencies of key parameters between the two dimensions limits its flexibility. In this study we present a method for pulse generation, which is based on a switching valve alternating between one pump that delivers the gradient and a second pump that delivers low eluotrophic strength for the pause state. Consequently, the dwell volume of the system was circumvented and 7.5, and 3.75 times shorter pulse widths could be generated at flow rates of 0.2, and 0.4 mL/min with satisfactory accuracies between programmed and observed mobile phase composition (relative deviation of 6.0 %). We investigated how key parameters including pulse width and step height, 2D gradient time and flow rate affected the peak capacity in PE-LC × LC. The conditions yielding the highest peak capacity for the PE-LC × LC- high-resolution mass spectrometry (HRMS) system were applied to a wastewater effluent sample. The results were compared to a one dimensional (1D)-LC-HRMS chromatogram. The peak capacity increased with a factor 34 from 112 for the 1D-LC run to 3770 for PE-LC × LC-HRMS after correction for undersampling. The analysis time for PE-LC × LC-HRMS was 12.1 h compared to 67.5 min for the 1D-LC-HRMS run. The purity of the mass spectra improved for PE-LC × LC-HRMS by a factor 2.6 (p-value 3.3 × 10−6) and 2.0 (p-value 2.5 × 10−3) for the low and high collision energy trace compared to the 1D-LC-HRMS analysis. Furthermore, the signal-to-noise ratio (S/N) was 4.2 times higher (range: 0.06–56.7, p-value 3.8 × 10−2) compared to the 1D-LC-HRMS separation based on 42 identified compounds. The improvements in S/N were explained by the lower peak volume obtained in the PE-LC × LC-HRMS.
Original languageEnglish
Article number465079
JournalJournal of Chromatography A
Volume1730
Number of pages12
ISSN0021-9673
DOIs
Publication statusPublished - 2024

Bibliographical note

Funding Information:
The authors would like to acknowledge David I. Pattison for technical assistance in the laboratory, and Selina Tisler for making the wastewater samples available and for valuable insights on the samples.

Funding Information:
The work was funded by the Innovation Fund Denmark project VANDALF , Grant Number: 9067-00032A , and the Novo Nordisk Foundation project The Matrix (Grant number: NNF19SA0059348 ).

Publisher Copyright:
© 2024

Keywords

  • Fundamentals
  • High-resolution mass spectrometry
  • Non-target screening
  • Pulsed elution-LCxLC
  • Wastewater analysis

Cite this