Abstract
AIMS: Stent graft placement is a safe and effective treatment option for vascular complications in the context of transcatheter aortic valve implantation (TAVI). This study aimed to provide long-term angiological follow-up of stent grafts used for this indication.
METHODS AND RESULTS: Seventy-one patients (64.8% female, log EuroScore 14.7 ± 6.8%) who had undergone TAVI between March 2010 and October 2015 with implantation of a Viabahn or Fluency stent graft to treat access-site or access-related vascular injury (ASARVI) were analyzed. Implantations were mostly due to access-site bleeding complications (83.1%) in the common femoral artery (97.1%). Follow-up was performed with duplex sonography in all patients after a median of 3.9 years after TAVI (interquartile range [IQR]: 895-1749 days). Ultrasound revealed tri- or biphasic flow patterns in 16.9% and 77.6%, respectively. Stent graft patency was 100% without signs of stent graft stenosis (mean peak velocity ratio 1.0 ± 0.2). Pseudo-aneurysms or endoleaks were diagnosed in 5.6% of patients. Additional fluoroscopic and/or computed tomography (CT)-imaging was available in 36.6% of patients and did not reveal any stent fracture.
CONCLUSION: Self-expanding stent grafts provide excellent long-term function with few complications when implanted in the context of TAVI-related ASARVI.
Original language | English |
---|---|
Journal | International Journal of Cardiology |
Volume | 281 |
Pages (from-to) | 42-46 |
Number of pages | 5 |
ISSN | 0167-5273 |
DOIs | |
Publication status | Published - 15 Apr 2019 |
Keywords
- Aged
- Aged, 80 and over
- Blood Vessel Prosthesis/adverse effects
- Cohort Studies
- Cross-Sectional Studies
- Female
- Follow-Up Studies
- Humans
- Male
- Stents/adverse effects
- Time Factors
- Tomography, X-Ray Computed/trends
- Transcatheter Aortic Valve Replacement/adverse effects
- Treatment Outcome
- Vascular System Injuries/diagnostic imaging