TY - JOUR
T1 - Telemetric Continuous Glucose Monitoring During the COVID-19 Pandemic in Isolated Hospitalized Patients in Denmark
T2 - A Randomized Controlled Exploratory Trial
AU - Klarskov, Carina Kirstine
AU - Windum, Nicole Avlund
AU - Olsen, Mikkel Thor
AU - Dungu, Arnold Matovu
AU - Jensen, Andreas Kryger
AU - Lindegaard, Birgitte
AU - Pedersen-Bjergaard, Ulrik
AU - Kristensen, Peter Lommer
PY - 2022
Y1 - 2022
N2 - Objective: To investigate whether telemetric continuous glucose monitoring (CGM) in hospitalized and isolated patients with diabetes mellitus and coronavirus disease 2019 (COVID-19) is associated with better glycemic outcomes and fewer patient health care worker contacts compared to blood glucose monitoring by traditional point-of-care (POC) glucose testing and to investigate the user aspect of implementing a CGM-system in-hospital.Materials and Methods: A randomized controlled exploratory trial was performed on hospitalized and isolated patients with diabetes and COVID-19 from May 2020 until February 2021 at Nordsj AE llands Hospital, Denmark. Participants were randomized to nonblinded telemetric CGM (as the only glucose monitoring method) or traditional POC glucose testing + blinded CGM. The primary endpoint was time in range (TIR) based on CGM data in both groups. A questionnaire about the user aspect of the CGM system was answered by health care personnel (HCP).Results: We included 64 participants in the analysis, 31 in the CGM group and 33 in the POC glucose group. TIR median was 46% for the CGM group and 68% for the POC glucose group (P = 0.368). The mean glucose value for the CGM group was 11.1 and 10.8 mmol/L in the POC glucose group (P = 0.372). CGM was associated with fewer POC glucose measurements (P < 0.001). Out of 30 HCPs, 28 preferred telemetric CGM over POC glucose testing.Conclusion: Remote glucose monitoring by CGM did not improve glycemic outcomes compared to traditional POC glucose testing, but was associated with fewer patient-personnel contacts, saving time for HCPs performing diabetes-related tasks. Most HCPs preferred CGM. The study is registered at http://www.clinicaltrials.gov (#NCT04430608).
AB - Objective: To investigate whether telemetric continuous glucose monitoring (CGM) in hospitalized and isolated patients with diabetes mellitus and coronavirus disease 2019 (COVID-19) is associated with better glycemic outcomes and fewer patient health care worker contacts compared to blood glucose monitoring by traditional point-of-care (POC) glucose testing and to investigate the user aspect of implementing a CGM-system in-hospital.Materials and Methods: A randomized controlled exploratory trial was performed on hospitalized and isolated patients with diabetes and COVID-19 from May 2020 until February 2021 at Nordsj AE llands Hospital, Denmark. Participants were randomized to nonblinded telemetric CGM (as the only glucose monitoring method) or traditional POC glucose testing + blinded CGM. The primary endpoint was time in range (TIR) based on CGM data in both groups. A questionnaire about the user aspect of the CGM system was answered by health care personnel (HCP).Results: We included 64 participants in the analysis, 31 in the CGM group and 33 in the POC glucose group. TIR median was 46% for the CGM group and 68% for the POC glucose group (P = 0.368). The mean glucose value for the CGM group was 11.1 and 10.8 mmol/L in the POC glucose group (P = 0.372). CGM was associated with fewer POC glucose measurements (P < 0.001). Out of 30 HCPs, 28 preferred telemetric CGM over POC glucose testing.Conclusion: Remote glucose monitoring by CGM did not improve glycemic outcomes compared to traditional POC glucose testing, but was associated with fewer patient-personnel contacts, saving time for HCPs performing diabetes-related tasks. Most HCPs preferred CGM. The study is registered at http://www.clinicaltrials.gov (#NCT04430608).
KW - COVID-19
KW - Diabetes mellitus
KW - Continuous glucose monitoring
KW - Isolation
KW - Infection
KW - Personal protective equipment
KW - Telemetric medicine
KW - HYPERGLYCEMIA
U2 - 10.1089/dia.2021.0291
DO - 10.1089/dia.2021.0291
M3 - Journal article
C2 - 34524009
VL - 24
JO - Diabetes Technology & Therapeutics
JF - Diabetes Technology & Therapeutics
SN - 1520-9156
IS - 2
ER -