N2 - Background: Paroxysmal atrial fibrillation (pAF) occurs sporadically and can impair athletic performance. Gold standard for diagnosis is surface electrocardiography (ECG), however, this requires AF to be sustained. Implantable loop recorders (ILRs) are routinely used for AF detection in human medicine. While ILR placement has been studied in horses, its AF detection performance is unknown. Objectives: (I) Validation of ILRs for AF detection in horses. (II) Determining pAF incidence using ILRs and estimate the positive predictive value (PPV). Study design: (I) Experimental study; (II) Longitudinal observational study. Methods: (I) Implantation of ILRs in 15 horses with AF and 13 horses in sinus rhythm. Holter ECGs were recorded at: 1, 4, 8, 12 and 16 weeks of AF. The ILR ECGs were compared with surface ECGs to assess diagnostic sensitivity and specificity. (II) Eighty horses (43 Warmbloods, 37 Standardbreds) with ILRs were monitored for 367 days [IQR 208–621]. Results: (I) ILRs detected AF on all recording days, in horses with AF, with a sensitivity of 66.1% (95% CI: 65.8–66.5) and a specificity of 99.99% (95% CI: 99.97–99.99). The sensitivity remained consistent across all time points. (II) The incidence of pAF was 6.3% (5/80). In horses with pAF, the PPV ranged from 8% to 87%. Increased body condition score (BCS > 6/9) was associated with an increased number of false positive episodes (p = 0.005). Main limitations: (I) Horses were stabled during the ECG recordings, and AF was induced, rather than naturally occurring pAF. (II) Integrated algorithm in this ILR is optimised for AF detection in humans using remote monitors. Additionally, sensing is affected by motion artefacts. Conclusion: The ILR reliably detected AF in resting horses, particularly in horses with normal BCS (6/9). The ILR proved useful to detect pAF and is recommended alongside Holter monitoring for diagnostic workup of horses with suspected pAF.
AB - Background: Paroxysmal atrial fibrillation (pAF) occurs sporadically and can impair athletic performance. Gold standard for diagnosis is surface electrocardiography (ECG), however, this requires AF to be sustained. Implantable loop recorders (ILRs) are routinely used for AF detection in human medicine. While ILR placement has been studied in horses, its AF detection performance is unknown. Objectives: (I) Validation of ILRs for AF detection in horses. (II) Determining pAF incidence using ILRs and estimate the positive predictive value (PPV). Study design: (I) Experimental study; (II) Longitudinal observational study. Methods: (I) Implantation of ILRs in 15 horses with AF and 13 horses in sinus rhythm. Holter ECGs were recorded at: 1, 4, 8, 12 and 16 weeks of AF. The ILR ECGs were compared with surface ECGs to assess diagnostic sensitivity and specificity. (II) Eighty horses (43 Warmbloods, 37 Standardbreds) with ILRs were monitored for 367 days [IQR 208–621]. Results: (I) ILRs detected AF on all recording days, in horses with AF, with a sensitivity of 66.1% (95% CI: 65.8–66.5) and a specificity of 99.99% (95% CI: 99.97–99.99). The sensitivity remained consistent across all time points. (II) The incidence of pAF was 6.3% (5/80). In horses with pAF, the PPV ranged from 8% to 87%. Increased body condition score (BCS > 6/9) was associated with an increased number of false positive episodes (p = 0.005). Main limitations: (I) Horses were stabled during the ECG recordings, and AF was induced, rather than naturally occurring pAF. (II) Integrated algorithm in this ILR is optimised for AF detection in humans using remote monitors. Additionally, sensing is affected by motion artefacts. Conclusion: The ILR reliably detected AF in resting horses, particularly in horses with normal BCS (6/9). The ILR proved useful to detect pAF and is recommended alongside Holter monitoring for diagnostic workup of horses with suspected pAF.
KW - arrhythmia
KW - continuous monitoring device
KW - horse
KW - long-term monitoring
KW - paroxysmal atrial fibrillation
KW - telemetry
U2 - 10.1111/evj.14112
DO - 10.1111/evj.14112
M3 - Journal article
C2 - 39031582
AN - SCOPUS:85196544967
JO - Equine Veterinary Journal
JF - Equine Veterinary Journal
SN - 0425-1644
ER -